Humidity and Temperature Sensors DVT-012, DVTc-012
$ 60.24
Category:
Extra Features
Premium Quality
Secure Payments
Satisfaction Guarantee
The "REGMIK" company manufactures humidity and temperature sensors with digital (DVTc-012) and analog (DVT-012) sensitive elements. The DVT-012 sensors use a Honeywell element as the sensitive element for humidity measurement, while the DVTc-012 sensors use Sensirion. Temperature measurements employ temperature sensors from the German company Heraeus.Humidity and temperature sensors are designed to convert the value of relative humidity in a gaseous medium and its temperature (excluding aggressive gases) into standard electrical signals:analog voltage (measured voltage value on the humidity sensor);I²C - digital sensors;0-10 V voltage - for digital and analog sensors;4-20 mA current - for digital and analog sensors;resistance (temperature values from temperature sensors Pt100, Pt500, or Pt1000) - for analog sensors;RS-485 (ModBus RTU protocol) - for digital sensors.The scope of humidity sensor application is very wide and includes:Maintaining the microclimate within specified limits in production equipped with humidity-sensitive electronic devices;Monitoring humidity indicators in office rooms and in everyday life;In utilities - in boiler rooms and water treatment stations to prevent condensation formation;Periodic control helps prevent mold and mildew formation on building walls or in storage;Control of technological processes;Monitoring of environmental parameters, etc.The material of protective fittings of the sensors is stainless steel grade 12X18H10T. Humidity and temperature sensors DVT-012, DVTc-012 do not allow moisture condensation.The multilayer construction of the sensitive element HIH4xxx provides excellent resistance to most application hazards such as wetting, dust, dirt, oils, and common chemical substances in the environment. Main characteristics of sensors based on HIH4xxx series elements:Cast thermosetting plastic housingNearly linear output voltage depending on relative humidityInterchangeability with laser trimmingLow power consumption designEnhanced accuracyFast response timeStable characteristics with low driftChemical resistanceThe converter operates stably within the recommended measurement range of humidity and temperature. Prolonged exposure to conditions outside the normal range, especially at humidity > 80%, may temporarily increase measurement errors. After returning to the normal range, it will slowly revert to factory parameters.Special caution should be taken when using the converter under high humidity conditions (> 98%) and near the dew point, as wetting may irreversibly damage the sensitive element.Other modifications of humidity sensors are also produced, which can be found by this link...